Dynamic Hip Screw Implant System / Libristo.pl
Dynamic Hip Screw Implant System

Kod: 07123136

Dynamic Hip Screw Implant System

Autor P. Regazzoni, Thomas P. Ruedi, R. Winquist, M. Allgower

The AOjASIF dynamic hip screw (DRS) has been designed primarily to stabilize trochanteric fractures of the hip. Selected fractures of the femoral neck and some subtrochanteric fractures are further indications for the DRS [40, 46] ... więcej

285


Dostępna u dostawcy
Wysyłamy za 14 - 18 dni
Dodaj do schowka

Zobacz książki o podobnej tematyce

Bon podarunkowy: Radość gwarantowana

Wzór bonu podarunkowegoDowiedz się więcej

Więcej informacji o Dynamic Hip Screw Implant System

Za ten zakup dostaniesz 166 punkty

Opis

The AOjASIF dynamic hip screw (DRS) has been designed primarily to stabilize trochanteric fractures of the hip. Selected fractures of the femoral neck and some subtrochanteric fractures are further indications for the DRS [40, 46]. The dynam ic condylar screw (DCS) has been developed for fractures of the distal femur and is now being tested clinically. The DRS and DCS are carefully coordinated with the preexisting ASIF standard sets of equipment for internal fixation of fractures. The concept of a sliding screw for trochanteric fractures is not new. The first author describing such an implant was Schumpelick [44]; he gives credit to Pohl [22], who was primarily a manufacturer working for Gerhardt Kiinscher. Re described the possibility of impaction at the fracture site with a sliding device. In the United States Clawson [7, 8] introduced the hip screw and found it to be extremely beneficial in trochanteric fractures. At approximately the same time, Massie [31, 32] and Pugh [39] designed the sliding-type flange nails, which offer similar intramedullary splinting with the possibility of fracture impaction. The following chapters describe the concept and design features of the DRS, as well as the details of the surgical technique. The application of the DRS for different types of fractures is illustrated with clinical examples. The results of 268 cases of trochanteric fractures treated with the DRS are presented and compared with results using the angled blade plate and Ender's nails. Finally, some laboratory tests are described.

Szczegóły książki

Kategoria Książki po angielsku Medicine Surgery Critical care surgery

285


250 000
zadowolonych klientów

Od roku 2008 obsłużyliśmy wielu miłośników książek, ale dla nas każdy był tym wyjątkowym.


Paczkomat 12,99 ZŁ 31975 punktów

Copyright! ©2008-24 libristo.pl Wszelkie prawa zastrzeżonePrywatnieCookies


Konto: Logowanie
Wszystkie książki świata w jednym miejscu. I co więcej w super cenach.

Koszyk ( pusty )

Kup za 299 zł i
zyskaj darmową dostawę.

Twoja lokalizacja: