Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults / Libristo.pl
Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults

Kod: 05283714

Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults

Autor Mahmoud Mossa

Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, - (Faculty of engineering-Minia university - Electrical engineering department), course: Electrical engineering (Renewable energy), la ... więcej

382.09


Dostępna u dostawcy
Wysyłamy za 14 - 18 dni
Dodaj do schowka

Zobacz książki o podobnej tematyce

Bon podarunkowy: Radość gwarantowana

Wzór bonu podarunkowegoDowiedz się więcej

Więcej informacji o Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults

Za ten zakup dostaniesz 221 punkty

Opis

Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, - (Faculty of engineering-Minia university - Electrical engineering department), course: Electrical engineering (Renewable energy), language: English, abstract: Wind electrical power systems are recently getting lot of attention, becausethey are cost competitive, environmental clean and safe renewable powersource, as compared with fossil fuel and nuclear power generation. A specialtype of induction generator, called a doubly fed induction generator (DFIG),is used extensively for high-power wind applications. They are used moreand more in wind turbine applications due to ease controllability, highenergy efficiency and improved power quality.This thesis aims to develop a method of a field orientation scheme forcontrol both the active and reactive powers of a DFIG driven by a windturbine.The proposed control system consists of a wind turbine that drives aDFIG connected to the utility grid through AC-DC-AC link. The maincontrol objective is to regulate the dc link voltage for operation at maximumavailable wind power.This is achieved by controlling the and axescomponents of voltages and currents for both rotor side and line sideconverters using PI controllers. The complete dynamic model of theproposed system is described in detail. Computer simulations have beencarried out in order to validate the effectiveness of the proposed systemduring the variation of wind speed. The results prove that , better overallperformances are achieved, quick recover from wind speed disturbances inaddition to good tracking ability.Generally, any abnormalities associated with grid asymmetrical faults aregoing to affect the system performance considerably. During grid faults,unbalanced currents cause negative effects like overheating problems andmechanical stress due to high torque pulsations that can damage the rotor shaft, gearbox or blade assembly. Therefore, the dynamic model of theDFIG, driven by a wind turbine during grid faults has been analyzed anddeveloped using the method of symmetrical components. The dynamicperformance of the DFIG during unbalanced grid conditions is analyzed anddescribed in detail using digital simulations.A novel fault ride-through (FRT) capability is proposed (i.e. the ability ofthe power system to remain connected to the grid during faults) with suitablecontrol strategy in this thesis. In this scheme, the input mechanical energy ofthe wind turbine during grid faults is stored and utilized at the moment offault clearance, instead of being dissipated in the resistors of the crowbarcircuit as in the existing FRT schemes. [...]

Szczegóły książki

Kategoria Książki po angielsku Technology, engineering, agriculture Technology: general issues

382.09

Ulubione w innej kategorii


250 000
zadowolonych klientów

Od roku 2008 obsłużyliśmy wielu miłośników książek, ale dla nas każdy był tym wyjątkowym.


Paczkomat 12,99 ZŁ 31975 punktów

Copyright! ©2008-24 libristo.pl Wszelkie prawa zastrzeżonePrywatnieCookies


Konto: Logowanie
Wszystkie książki świata w jednym miejscu. I co więcej w super cenach.

Koszyk ( pusty )

Kup za 299 zł i
zyskaj darmową dostawę.

Twoja lokalizacja: